15KW Manual Wet Cleaning

Panels are coated with Anti-dust Solar Shield in December 2019

Existing Challenges

As plant is situated in a busy MIDC area in Mumbai, It has following problems which leads to energy generation loss from solar panels:

  1. Fine layer of dust on solar panels due to nearby construction site.
  2. Bird droppings.
  3. Small yellow drops on panels.
  4. Black chemical drops on panels.

Field Operation

  1. No of workers- 2
  2. Instrument use- telescopic wiper, Microfiber brush
  3. Type of cleaning- wet cleaning on Anti-dust Solar Shield coated panels
  4. No of cleaning cycles per month- 2
cleaning-with-workers

Field Results

cleaning-results

Progress Chart

progress-chart
progress-chart-2

Conclusion

With the application of anti-dust solar shield and regular plant cleaning generation of solar power plant has been increased by 26.72% comparing with  the generation of last year of same month.

 